high-capacity-static-load-testing
December 4, 2018

High Capacity Static Load Testing for Tampa’s West Extension of the Selmon Expressway

AFT completes another successful high capacity load test. Shown is our 1,500 ton top down static test system, setup in the median of busy Gandy Blvd in South Tampa. All part of the foundation construction by Kiewit for the new Lee Roy Selmon Expressway West Extension project. As usual, we utilized fully automated instrumentation for high precision measurements monitored from a safe distance away. Contact

lateral-static-test-ability
August 23, 2018

1,000 kips of Lateral Static Load Test Ability

Simplicity and highly effective. AFT upgraded our lateral static load test capabilities with the addition of this 1,000 kip lateral test strut. Ideal for Drilled Shafts and Pile groups. Push or pull while allowing the pile head to freely rotate. Allows accurate back fitting of results to modeling programs. We apply fully automated precision electronic instrumentation above ground, embedment gages, and reusable downhole instruments for

aftcell-mele-in-hawaii
October 31, 2017

AFTCell Mele in Hawaii

AFT is proud to be a part of the latest phase of the Honolulu Rail Transit project working with the JV of Shimick Traylor Granite. This is the third segment of the project known as the Airport Guideway and Stations Design Build Contract. It includes a 5.15-mile segment of elevated guideway and four stations all supported on Drilled Shaft foundations. AFT-Cell’s were used extensively on the project but

small-bore-big-results
August 31, 2017

Smallbore = Big Results with AFT-Cell

AFT recently achieved a load test record for the Tampa Bay Area. To maximize the side resistance that could be mobilized in a test shaft, we worked with our client Case Atlantic and the geotechnical engineer Terracon to design a test shaft with the optimal diameter to test capacity. The team finally decided on a 3 foot (~1 m) diameter shaft, 94 feet (28.6 m) below

north-american-record-drill-shaft
March 31, 2017

North American Record Drilled Shaft at 340 feet

AFT together with Malcolm Drilling Company has recently accomplished what has never been done in the USA. Drilled shafts were installed to an astounding depth of 340 feet (104 meters) and load tested with our AFT-Cell Bi-Directional Load Test system. Two levels of AFT-Cell assemblies with three cells per level were used to apply test loads in excess of 30,000 kips. The new Oceanwide Center project in

aft-cell-completes-22000kips-load-test
March 5, 2016

AFT-Cell Completes 22,000 kip Load Test for Project Neon in Las Vegas

AFT achieved a personal best completing an amazing 22,000 kip load test with our new AFT-Cell Bi-Directional load cell. Pictured here is a high capacity, multiple AFT-Cell installation, for an 8 foot diameter drilled shaft. AFT is working with our long time client, Kiewit, and their drilled shaft subcontractor Hayward Baker to deliver another high quality foundation load testing program.

port-of-seattle-terminal-5-expansion
January 18, 2016

Port of Seattle Terminal 5 Expansion Project

Seattle, Washington – Gearing up for the Port of Seattle Terminal 5 Expansion pile load test program, AFT installed embedded strain gage instrumentation in piles at Concrete Technology Corporation’s first class casting yard in Tacoma, Washington. The pile load test program includes STATNAMIC™ testing of strain instrumented 24-inch octagonal piles with single piece lengths of 178 feet and 24-inch and 30-inch open end pipe piles with lengths over 170 feet.

base-grouted-drilled-shafts-for-honolulu-light-rail-project
November 30, 2015

Base Grouted Drilled Shafts for Honolulu Light Rail Project

Honolulu, Hawaii –The Honolulu Light Rail Project project is taking impressive shape. Applied Foundation Testing is proud to be a part of this landmark structure on the island of Oahu, Hawaii, supported on our post grouted drilled shafts. Kiewit Infrastructure West Co. in conjunction with AFT used base grouting for the drilled shafts to reduce shaft length and increase constructability.  AFT is also performing CSL testing and